Guides / Properties and drug-likeness

veberoral-bioavailabilityrotatable-bondspolar-surface-areardkit

Veber's rules for oral bioavailability, rotatable bonds and PSA

Veber's rules link good oral bioavailability to 10 or fewer rotatable bonds and a polar surface area of at most 140 Ų, based on rat data published in 2002.

Updated 4 min read

Veber's rules predict a higher chance of good oral bioavailability when a compound has 10 or fewer rotatable bonds and a polar surface area of 140 Ų or less. Daniel Veber and colleagues derived them in 2002 from rat pharmacokinetic data on a large set of drug candidates. A total of 12 or fewer hydrogen-bond donors and acceptors can replace the polar surface criterion. The same analysis found that a molecular weight cut-off of 500 separated good from poor compounds less well than flexibility and polarity did.

The two criteria

A compound meeting both had a higher probability of useful oral bioavailability in the rat. A compound failing either had a lower probability. Like Lipinski's rule, these are thresholds placed on a trend. They are not a model of any single molecule.

What the data behind the rules showed

Veber's team analysed oral bioavailability measured in rats for more than 1100 drug candidates studied at SmithKline Beecham. Molecular weight and the other Lipinski properties correlate with each other, since larger molecules tend to have more rotatable bonds and more polar surface. The analysis pulled those effects apart. Rotatable bonds and polar surface area each predicted bioavailability independently of molecular weight. The authors suggested that this overlap explains much of the past success of the molecular weight cut-off.

The same paper looked at permeation through an artificial membrane. Lower polar surface area tracked faster permeation better than calculated logP did, and more rotatable bonds slowed permeation. The rotatable-bond count did not correlate with clearance in the rat. That suggests flexibility acts mainly on absorption rather than on metabolism. Polar surface matters because each exposed polar group must shed its water before the molecule enters a lipid layer. The guide on TPSA describes how that surface is estimated from a 2D structure.

Running Veber's rules in RDKit

The snippet applies both criteria with RDKit's default rotatable-bond count and Ertl's TPSA.

from rdkit import Chem
from rdkit.Chem import rdMolDescriptors

drugs = {
    "ibuprofen": "CC(C)Cc1ccc(cc1)C(C)C(=O)O",
    "paracetamol": "CC(=O)Nc1ccc(O)cc1",
    "imatinib": "Cc1ccc(NC(=O)c2ccc(CN3CCN(C)CC3)cc2)cc1Nc1nccc(-c2cccnc2)n1",
    "atorvastatin": "CC(C)c1c(C(=O)Nc2ccccc2)c(-c2ccccc2)"
                    "c(-c2ccc(F)cc2)n1CC[C@@H](O)C[C@@H](O)CC(=O)O",
}

def veber(mol):
    rotb = rdMolDescriptors.CalcNumRotatableBonds(mol)
    tpsa = rdMolDescriptors.CalcTPSA(mol)
    return rotb, round(tpsa, 1), rotb <= 10 and tpsa <= 140

for name, smi in drugs.items():
    print(name, *veber(Chem.MolFromSmiles(smi)))
# ibuprofen 4 37.3 True
# paracetamol 1 49.3 True
# imatinib 7 86.3 True
# atorvastatin 12 111.8 False

Atorvastatin fails on flexibility, with 12 rotatable bonds, while its TPSA of 111.79 Ų is within range. It is nonetheless an oral drug. Imatinib passes both criteria comfortably. The guide to rotatable bonds and flexibility explains why atorvastatin's dihydroxy acid side chain weighs so heavily in the count. Molecule Analysis shows an RDKit property profile for any compound you enter.

Why the counting method matters

The rotatable-bond count depends on its definition. Both of RDKit's main options ignore bonds to terminal heavy atoms such as methyls and hydroxyls. The default, called strict, also excludes amide and ester bonds, as its documentation states. The non-strict option counts them. Paracetamol has 1 rotatable bond under the strict definition and 2 under the non-strict one. Atorvastatin goes from 12 to 13. Near the threshold of 10, that choice decides the outcome.

The polar surface value depends on method as well. Most groups now use Ertl's TPSA as the stand-in for Veber's polar surface. Whether sulfur and phosphorus are counted can move a compound across the 140 Ų line, so record the setting along with the result.

Veber and Lipinski together

The two rule sets overlap. Rotatable bonds and polar surface rise with molecular weight, and donor and acceptor counts feed directly into polar surface. Many filtering pipelines apply both sets and report each failure separately rather than a combined score. A compound that passes Lipinski but fails Veber is usually a flexible, chain-rich molecule. A compound that fails Lipinski on molecular weight but passes Veber is often compact and rigid, and some teams accept that profile.

Limits of a rule built on rat data

Key points

Questions people ask

What are Veber's rules?
Veber's rules state that a compound is more likely to have good oral bioavailability when it has 10 or fewer rotatable bonds and a polar surface area of 140 Ų or less. A total of 12 or fewer hydrogen-bond donors and acceptors can replace the polar surface criterion. Daniel Veber and colleagues published them in 2002.
How do Veber's rules differ from Lipinski's rule of five?
Lipinski's rule looks at molecular weight, logP and donor and acceptor counts. Veber's analysis added molecular flexibility through the rotatable-bond count and used polar surface area in place of separate donor and acceptor limits. It also found that a molecular weight cut-off of 500 separated good from poor compounds less well than these two properties.
Were Veber's rules derived from human data?
No. They came from oral bioavailability measured in rats for a large set of drug candidates. Rat and human bioavailability often differ because of species differences in metabolism, so the rules describe a trend that tends to carry over rather than a human prediction.

Further reading

In practice: The ADMET dashboard computes the RDKit property profile and the Lipinski flags for any compound; the numbers in these guides are the ones it shows.

← All guides